_core_eia923__yearly_fgd_operation_maintenance

package: pudl

Annual time series of flue gas desulfurization (FGD) operation and maintenance expenses at generation facilities.

Most-recent data:

2024

Processing:

Data has been cleaned but not tidied/normalized. Published only temporarily and may be removed without notice.

Source:

EIA Form 923 -- Power Plant Operations Report (Schedule 8C)

Primary key:

plant_id_eia, report_date, so2_control_id_eia

Usage Warnings

  • Some years use a slightly different data definition.

Additional Details

From 2008-2011 this table also reported operational characteristics that are now reported in 923 Air Emissions Control Info.

Note: This table has been cleaned, but not harvested with other EIA 923 or 860 data. The same variables present in this table may show up in other _core tables in other years. Once this table has been harvested, it will be removed from the PUDL database.

Columns
report_date

Date reported.

plant_id_eia

The unique six-digit facility identification number, also called an ORISPL, assigned by the Energy Information Administration.

so2_control_id_eia

Sulfur dioxide control identification number. This ID is not a unique identifier.

opex_fgd_feed_materials_chemical

Annual operation and maintenance expenditures for feed materials and chemicals for flue gas desulfurization equipment, excluding electricity.

opex_fgd_labor_supervision

Annual operation and maintenance expenditures for labor and supervision of flue gas desulfurization equipment, excluding electricity.

opex_fgd_land_acquisition

Annual operation and maintenance expenditures for land acquisition for flue gas desulfurization equipment, excluding electricity.

opex_fgd_maintenance_material_other

Annual operation and maintenance expenditures for maintenance, materials and all other costs of flue gas desulfurization equipment, excluding electricity

opex_fgd_waste_disposal

Annual operation and maintenance expenditures for waste disposal, excluding electricity.

opex_fgd_total_cost

Annual total cost of operation and maintenance expenditures on flue gas desulfurization equipment, excluding electricity

fgd_control_flag

Indicates whether or not a plant has a flue gas desulfurization control unit.

fgd_operational_status_code

Operating status code for flue gas desulfurization equipment.

fgd_hours_in_service

Number of hours the flue gas desulfurization equipment was in operation during the year.

fgd_electricity_consumption_mwh

Electric power consumed by the flue gas desulfurization unit (in MWh).

fgd_sorbent_consumption_tons

Quantity of flue gas desulfurization sorbent used, to the nearest 100 ton.

so2_removal_efficiency_tested

The tested efficiency for the removal of sulfur dioxide at 100 percent load. If not tested at 100 percent load, then the load at which the test was conducted is included as a comment on Schedule 9. If no test was conducted, the test date and tested efficiency field should be blank. Ranges from 0 to 1.

so2_removal_efficiency_annual

Sulfur dioxide removal efficiency, based on the annual operating factor, which is defined as annual fuel consumption (MMBTU) divided by the product of the boiler design firing rate (MMBTU per hour) and hours of operation per year.When actual data are not available, estimates are provided based on equipment design performance specifications. Ranges from 0 to 1.

so2_test_date

Date of most recent test for sulfur dioxide removal efficiency.

data_maturity

Maturity of the source data published by EIA that is reflected in this record. EIA releases data incrementally over time, including monthly updates, annual year-to-date updates, provisional early releases of annual data, and final annual release data that is not expected to change further. Records sourced from multiple upstream EIA datasets may have no well defined data maturity. Records whose values have been inferred within PUDL will also have no data maturity.